15
6 - GPIB Communication6 - GPIB Communication
6 - GPIB Communication6 - GPIB Communication
6 - GPIB Communication
GPIB (IEEE-488)
The IEEE-488 or GPIB (General Purpose Interface Bus)
provides direct connection and control of the 5300 from
any appropriately equipped computer for the purpose
of data acquisition and display. MAGTROL factory
assistance is available if required.
HARDWARE INSTALLATION
A GPIB interface requires installation of an interface
card in the host computer and driver software resident
on the PC's hard disk. MAGTROL can supply the
National Instruments Corp. GPIB-PC2A
®
interface for
IBM
®
or compatible PCs.
SOFTWARE INSTALLATION
Formatting and initialization assistance is available from
MAGTROL Customer Service.
All GPIB data acquisition systems require the use of
termination characters to signal the conclusion of a data
exchange. The 5300 uses the Hewlett Packard - HPIB
standard ASCII termination characters "Carriage Return
(CR) and Line Feed (LF)," in that order. On a read cycle,
the 5300 looks for the CR-LF to signal completion of
an instruction and transmits these characters upon
conclusion of a data write cycle.
PRIMARY ADDRESS
All instruments serviced on the bus have a separate
primary address code. The factory setting for the 5300
is fourteen (14). This code can be changed by changing
the settings of the DIP switch that are located on the
rear panel next to the GPIB connector. Change this
address only if there is a bus addressing conflict with
other instrumentation. Refer to the table in Figure 13
to set the DIP switch pattern - set to address 14.
Some PC interfaces (National GPIB-PC2A) will access
0 to 15 (4 bit) primary address numbers only. Other
interfaces may access up to 31 (5 bit code). The 5300
PA code range uses the 5 bit code format. Before
selecting a value greater than 15, check that your
particular interface has the 5 bit code capability.
Figure 13. GPIB Address Selection
(Address 14 shown)
SWITCH SEGMENT
12345
LSB MSB
ADDRESS
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
124816
1
0
1 2 3 4 5 6 7 8
Not Used
Page view 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 39 40

Comments to this Manuals

No comments