4
Magtrol Model 5300 Three Phase Power Analyzer
Chapter 2 - Specifications
DIGITAL
Processing:
Integration period = 0.10 second.
Display update time = 2 readings per second.
IEEE-488 (GPIB):
Synchronized = 0.1 sec. per reading
Non-synchronized is 0.04 to 0.07 sec per
reading.
MEASUREMENT ACCURACY
Specified test conditions: Ambient temperature of 72°
± 10°F and power factor of 0.1 to 1.0, lead or lag.
VOLTAGE - DC
+
(0.1% of reading + 0.2% of range)
VOLTAGE - AC:
10 Hz to < 20 Hz
+
1.0% of range
20 Hz to < 45 Hz
+
(0.2% of reading + 0.3% of range)
45 Hz to < 10 kHz
+
(0.1% of reading + 0.2% of range)
10 kHz to 20 kHz
+
(0.2% of reading + 0.5% of range)
CURRENT - DC 25 and 100 Amp Ranges
+
(0.1% of reading + 0.2% of range)
CURRENT - AC:
5 Amp Range
10 Hz to < 20 Hz
+
1.0% of range
20 Hz to < 45 Hz
+
(0.2% of reading + 0.3% of range)
45 Hz to < 1 kHz
+
(0.1% of reading + 0.2% of range)
1 kHz to < 5 kHz
+
(0.2% of reading + 0.3% of range)
5 kHz to < 10 kHz
+
(1.0% of reading + 1.0% of range)
10 kHz to 20 kHz
+
(2.0% of reading + 2.0% of range)
25 Amp Range
10 Hz to < 5 kHz
same as 5 Amp range
5 kHz to 10 kHz
+
(2.0% of reading + 2.0% of range)
100 Amp Range
10 Hz to < 1 kHz
+
0.5% of rng
1 kHz to 2 kHz
+
(2.0% of reading + 2.0% of range)
POWER - DC
+
(0.1% of reading + 0.2% of VA range)
POWER - AC
± [(0.1% of reading + 0.2% of (Amps
range × Volts range)]
POWER FACTOR
+
(VA error ± W error)
CREST FACTOR
Exceeds 3:1 (at 50% of range full scale)
TEMPERATURE
COEFFICIENT
+
0.01% of range per deg. C maximum
DISPLAY
Digital display error ± 1 LSB.
ACCURACY CERTIFICATION
All instruments are shipped with a Certificate of
Calibration from Magtrol Inc. Magtrol policies and
procedures comply with MIL-STD-45662A.
Measurement standards are traceable to the National
Institute of Standards and Technology (NIST).
Instrument calibration every six calendar months is
necessary to maintain full compliance with all
specifications. If a one year calibration cycle is used,
all accuracy specifications are reduced by 0.1%. After
one calendar year, the instrument is considered to be
out of calibration.