Deni 5300 Specifications

Browse online or download Specifications for Measuring, testing & control Deni 5300. Deni 5300 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Model 5300Model 5300
Model 5300Model 5300
Model 5300
Three PhaseThree Phase
Three PhaseThree Phase
Three Phase
PP
PP
P
ower Analyzerower Analyzer
ower Analyzerower Analyzer
ower Analyzer
UserUser
UserUser
User
’s Manual’s Manual
’s Manual’s Manual
’s Manual
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Model 5300

Model 5300Model 5300Model 5300Model 5300Model 5300Three PhaseThree PhaseThree PhaseThree PhaseThree PhasePPPPPower Analyzerower Analyzerower Analyzero

Page 2 - MAGTROL, INC

4Magtrol Model 5300 Three Phase Power AnalyzerChapter 2 - SpecificationsDIGITAL• Processing:Integration period = 0.10 second.Display update time = 2 r

Page 3

53 - Connecting the 53003 - Connecting the 53003 - Connecting the 53003 - Connecting the 53003 - Connecting the 5300Always install a properly rated ci

Page 4

6Magtrol Model 5300 Three Phase Power AnalyzerChapter 3 - Connecting the 5300SINGLE PHASE AC OR DCCONNECTIONSSee figure 2.NOTE: Connections are shown

Page 5

7Magtrol Model 5300 Three Phase Power Analyzer Chapter 3 - Connecting the 53003-PHASE 3-WIRE DELTA CONNECTIONSThe power dissipated in each phase (PØ)

Page 6

8Magtrol Model 5300 Three Phase Power AnalyzerChapter 3 - Connecting the 53003-PHASE, 4-WIRE WYE CONNECTIONSFigure 5. 3-Phase, 4-Wire WYE ConnectionsI

Page 7 - 1 - Introduction

94 - Operation4 - Operation4 - Operation4 - Operation4 - OperationRead Section 1 and make sure unit is connected properly(see Section 3) before procee

Page 8 - Chapter 1 - Introduction

10Magtrol Model 5300 Three Phase Power AnalyzerChapter 4 - OperationMODE SELECTIONSFigure 7. Mode SelectionsHOLD AVG PF PH.V.MODE HOLDThe HOLD push-bu

Page 9 - 2 - Specifications

11Magtrol Model 5300 Three Phase Power AnalyzerChapter 4 - OperationDISPLAY SELECTIONSFigure 8. Display SelectionsØ1 Ø2 Ø3 KWΣDISPLAY Ø1, Ø2, Ø3Indivi

Page 10 - ACCURACY CERTIFICATION

12Magtrol Model 5300 Three Phase Power AnalyzerChapter 4 - OperationAMPERES RANGEFigure 10. Current Range Selections5 25 100 AUTO5, 25 and 100 Amperes

Page 11 - 3 - Connecting the 5300

135 - CT/PT Installation5 - CT/PT Installation5 - CT/PT Installation5 - CT/PT Installation5 - CT/PT InstallationExternal current and potential transfo

Page 12 - CONNECTIONS

While every precaution has been exercised in the compilation ofthis document, Magtrol, Inc. assumes no responsibility for errorsor omissions. Addition

Page 13 - VOLTAGE SENSE

14Magtrol Model 5300 Three Phase Power AnalyzerChapter 5 - CT/PT InstallationCHANGING OR REMOVING CT/PTVALUESTo modify a value, simply overwrite the e

Page 14

156 - GPIB Communication6 - GPIB Communication6 - GPIB Communication6 - GPIB Communication6 - GPIB CommunicationGPIB (IEEE-488)The IEEE-488 or GPIB (G

Page 15 - 4 - Operation

167 - 5300 P7 - 5300 P7 - 5300 P7 - 5300 P7 - 5300 PA Instruction SetA Instruction SetA Instruction SetA Instruction SetA Instruction SetPC TO 5300 PA

Page 16 - V I V I V I

17Magtrol Model 5300 Three Phase Power AnalyzerChapter 7 - Instruction SetThis string transmits volts, watts and amps. To get linevoltage, power facto

Page 17 - 150 300 600 AUTO

18Magtrol Model 5300 Three Phase Power AnalyzerChapter 7- Instruction Set'Read 5300 PA full data - Magtrol Inc., 91 rt'Primary address set t

Page 18 - ANALOG OUTPUT OPTION

198 - Operating P8 - Operating P8 - Operating P8 - Operating P8 - Operating PrinciplesrinciplesrinciplesrinciplesrinciplesThe Magtrol 5300 PA uses the

Page 19 - 5 - CT/PT Installation

20Magtrol Model 5300 Three Phase Power AnalyzerChapter 8 - Operating PrinciplesVrms= dtT0t1V2Vo=10XYCosQVrms=dtt1T0V2Vrms=tdtT10V2V/F CONV.KhzVOLT.070

Page 20 - CHANGING OR REMOVING CT/PT

219 - Calibration9 - Calibration9 - Calibration9 - Calibration9 - CalibrationGENERALComplete calibration of the 5300 PA is beyond thecapabilities of m

Page 21 - 6 - GPIB Communication

22Magtrol Model 5300 Three Phase Power AnalyzerChapter 9 - CalibrationSince the current calibrator output is usually a lowimpedance with low complianc

Page 22 - "FULL" INSTRUCTION

23Magtrol Model 5300 Three Phase Power AnalyzerChapter 9 - CalibrationAMPERES CALIBRATION CHECKDC:1. On the 5300, press the 5 AMPERES range push-butto

Page 23 - LINE n PHASE n

iiiTTTTTable of Contentsable of Contentsable of Contentsable of Contentsable of ContentsSALES AND TECHNICAL ASSISTANCE ...

Page 24

24Magtrol Model 5300 Three Phase Power AnalyzerChapter 9 - CalibrationVOLTS ZERO1. Disable the auto zero function, refer to SpecialFunctions in Sectio

Page 25 - ANALOG PROCESSING

25Magtrol Model 5300 Three Phase Power AnalyzerChapter 9 - Calibration NOTE: Calibration on the 25 and 100Amps ranges may have to bedone at less than

Page 26 - POLYPHASE LINE BALANCE

26Appendix AAppendix AAppendix AAppendix AAppendix A: Schematic Drawings: Schematic Drawings: Schematic Drawings: Schematic Drawings: Schematic D

Page 27 - TEST SETUP

27Magtrol Model 5300 Three Phase Power Analyzer Appendix A: Schematic DrawingsCIRCUIT BOARD 78B145 - DIGITAL READOUT & MPUU64Q3Q69274HC3731Q5874D

Page 28 - VOLTS CALIBRATION CHECK

28Magtrol Model 5300 Three Phase Power AnalyzerAppendix A: Schematic DrawingsCIRCUIT BOARD 78B146 - ANALOG INPUT BOARDU9x200x100914x1010151612113-78-

Page 29 - MINOR ADJUSTMENT (IF NEEDED)

29Magtrol Model 5300 Three Phase Power Analyzer Appendix A: Schematic DrawingsCIRCUIT BOARD 78B147 - CONVERTER BOARDR2420K+15VC13.001U5Vo+V12+IN14132

Page 30 - AMPERES SCALE FACTOR

30Magtrol Model 5300 Three Phase Power AnalyzerAppendix A: Schematic DrawingsCIRCUIT BOARD 78B149 - SWITCHBOARDC1R3200R4200R1200R2200J4SW3FRONT VIEWS

Page 31 - WATTS SCALE FACTOR

31Magtrol Model 5300 Three Phase Power Analyzer Appendix A: Schematic DrawingsCIRCUIT BOARD 78B153 - SWITCH INTERFACECD4518EN10Q314RSTCD4518EN26RSTQ3

Page 32 - LSD MSD LSD

32Magtrol Model 5300 Three Phase Power AnalyzerAppendix A: Schematic DrawingsCIRCUIT BOARD 78B154 - COUNTERS BOARDU31Q3Q2643527EN Q1RST14520Q0CKQ314Q

Page 33

33Magtrol Model 5300 Three Phase Power Analyzer Appendix A: Schematic DrawingsCIRCUIT BOARD 78B175BR1PD05T114A-20-109467121013C4.1uFC31uFC14700uFC21u

Page 34

ivFigure 4. 3-phase, 3-Wire WYE Connections ... 73-Phase,

Page 35

Magtrol, Inc. warrants its products to be free from defects in material and workmanship under normal use andservice for a period of one (1) year from

Page 36

v"SGL" INSTRUCTION ...

Page 37

viThis page intentionally left blank.

Page 38

1ABBREVIATIONSPA - Model 5300 Power Analyzer.GPIB - IEEE-488 Instrument Bus Standard.LED - front panel indicator light.A, V, W, PF and VA: Amperes, Vo

Page 39 - CIRCUIT BOARD 78B175

2Magtrol Model 5300 Three Phase Power AnalyzerChapter 1 - IntroductionINSTALLATIONORIENTATIONThe 5300 PA must be mounted within ± 20 degreesfrom horiz

Page 40

32 - Specifications2 - Specifications2 - Specifications2 - Specifications2 - SpecificationsVOLTAGEThree DC and AC Ranges:• 150, 300, and 600 Volts DC