A Instruction SetA Instruction Set
A Instruction SetA Instruction Set
A Instruction Set
PC TO 5300 PA
A5, A25, A100
AMPERES RANGE selection.
V150, V300, V600
VOLTAGE RANGE selection.
AA
AMPS AUTO ran
e ON.
VA
VOLTS AUTO ran
e ON.
FULL
Sets data FORMAT to AMPS,
VOLTS, WATTS for 3 phases.
See 5300 PA TO PC.
SGL
Sets data output format = to
front panel display. See 5300
PA to PC.
SYNC
GPIB data output rate is
synchronized to 0.10 sec. bus
output rate. See DATA RATE.
OPEN
Data OUTPUT is transmitted
upon request. See OPEN
INSTRUCTION.
SP1, SP2, SP3
Selects PHASE 1, 2, or 3.
SPA
Selects ALL PHASES (same
as pressin
Ø1, Ø2 and Ø3
simultaneously).
LV
Select to read LINE VOLTAGE.
PV
Select to read each PHASE
VOLTAGE.
KW
select to read KILOWATTS
W
Select to read PHASE WATTS.
P
Select to read POWER
FACTOR.
I, IC
Avera
in
ON, Avera
in
OFF.
H, HC
HOLD ON, HOLD OFF.
L, LC
LOCKOUT, and LOCKOUT
CLEAR of all front panel push
switches.
AZ
Cancel of AUTO ZERO
function.
CT, PT
CANCEL, or ENTER data for
current or potential transformer
calibration.
RES
Soft RESET of PA (same as
power on).
In addition to the standard instructions listed in the table
on the left, there are special instructions for reading and
writing directly to the PA memory elements.
A specific program running in the host computer is
necessary. If you have a special situation where you
want direct memory access to alter 5300 PA functions
or change calibration, please contact Magtrol for
software assistance.
5300 PA TO PC
There are two choices for VOLTS, AMPS and WATTS
data format. Before you execute a read statement, it is
necessary to instruct the PA as to which data format
you wish to receive. This selection is retained by the
PA and becomes the default mode used for subsequent
data transmissions.
"SGL" INSTRUCTION
Sets the data format to a string length of 24 ASCII
characters, including carriage return and line feed
combination (••).
A=nn.nnV=nnn.nW=nnnn.n••
n (as shown) is any integer number 0 through 9
V (as shown) is volts
W (as shown) is watts
P is power factor
K is kilowatts
•• is carriage return and line feed combination
NOTE: Use leading zeros to maintain a
fixed string length.
"FULL" INSTRUCTION
Data for all 3-phases is supplied. The string is 68
contiguous ASCII characters:
A=xx.xxV=xxx.xW=xxxx.xA=yy.yyV=yyy.yW=yyyy.yA=zz.zzV=zzz.zW=zzzz.z••
x is an integer number 0 through 9 for phase 1.
y is an integer number 0 through 9 for phase 2.
z is an integer number 0 through 9 for phase 3.